INDEX Section 1:...General Section 2:...Structural Design Section 3:...Basic Material Specifications Section 4:...Structural Section 5:...Roof and Wall Covering Section 6:...Miscellaneous Material Specifications Section 7:...Accessories Section 8:...Erection Section 9:...Anchorage and Foundations
1.1. SCOPE
1.1.1. These specifications cover the materials and the fabrication of building materials manufactured by WedgCor, Inc. which shall be designed and erected in accordance with these specifications and accompanying drawings supplied with building materials. Erection by others.
1.1.2. The material furnished shall include the structural framing, roof panels, wall panels, bracing, fasteners, sealants, flashing and all other parts for a complete building system (except anchor bolts and all items embedded in the concrete.) Overhead doors, insulation, etc.... are not considered part of the building system and should be supplied by others.
1.2. BUILDING DESCRIPTION (CIB models)
![]() |
![]() |
1.3. BUILDING TERMINOLOGY
![]() |
![]() |
1.4. DRAWINGS AND CERTIFICATION
1.4.l. WedgCor, Inc. shall furnish approval erection drawings which include anchor bolt plans, wall and roof elevations for framing and sheeting, frame cross sections and general details to show clearly the proper assembly of all building components. Final erection drawings and shipping list will be delivered with the building.
1.4.2. A qualified Professional Engineer shall certify that the building design meets the requirements of the specifications and conforms to good engineering practices, for the loading conditions requested. (Please be specific).
1.4.3. Engineer letter of certification and engineer stamped drawings supplied upon request.
![]() |
2.1.GENERAL
2.1.1. All structural steel of hot-rolled shapes and built-up welded sections shall be designed in accordance with AISC's eighth edition "Specifications for the Design, Fabrication, and Erection of Structural Steel for Buildings".
2.1.2. Cold-Formed steel members shall be designed in accordance with AISI's latest edition of "Specifications for the Design of Cold-Formed Steel Structural Members".
2.2. DESIGN LOADS
2.2.l. Live loads imposed upon the roof shall be applied on the horizontal roof projection and shall be20, 25, 30, 40, 50 PSF, or as requested by the purchaser. The building will be designed as per any one of the following applicable building codes; UBC, BOCA, SBC, SFBC, and NBC (National Building Code of Canada). UBC (Uniform Building Code) is standard unless otherwise specified. All buildings are designed as per MBMA standards.
2.2.2. Wind Loads: Structural members and systems providing the stability for the building shall be designed for the velocity pressures set forth in the above building codes.
2.2.3. Auxiliary loads such as crane loads, mezzanine loads or excessive collateral loads are obtained by special request.
2.2.4. All load requirements are the responsibility of the builder, architect or owner. Please verify your code requirements with your local building department.
3.1. PRIMARY FRAMING
3.1.1. All hot-rolled steel plate used in fabrication of rigid frames shall conform to the requirements of ASTM Specification A-572. Minimum yield point shall be 50,000 PSI.
3.1.2. AB hot-rolled steel sheets shall conform to the requirements of ASTM Specification A-570, Grade 50.
3.1.3. Beyond 1/4" and up, flange material (bars) shall be ASTM A-36 modified to 50 KSI yield.
3.2. SECONDARY FRAMING
![]() |
3.3. ROOF AND WALL COVERING
![]() |
3.4. STRUCTURAL PAINTING
3.4.1. All structural framing members that are not galvanized shall be cleaned to remove all dirt, grease, oil and loose mill scale and shall be given one coat of shop primer.
3.4.2. Red primer shall have superior hiding powers.
3.4.3. The primer coat thickness shall be a minimum of one mil.
3.5. PANEL PAINTING
3.5.1. G-90 galvanized panel shall be pre-treated, then primed for superior resistance to corrosion before application of color coating.
3.5.2. The finish coat for painted steel panels, when required, shall be minimum 1 mil thickness silicone film and baked to a minimum temperature of 435 degrees F. The silicone polyester panels (except white) shall be pigmented with color pigments of a fade resistant type to help insure long color life. The painted panels shall not show excessive chalking, cracking or loss of adhesion during its warranty period.
3.5.3. Pre-treating and color coating process shall be applied by a reputable coating firm prior to roll forming. Warranty shall be provided upon request.
3.5.4. Colors shall be selected from WedgCor, Inc. Standard Colors.
4.1.GENERAL
![]() |
4.2. PRIMARY FRAMING
4.2.1. All rigid frames shall be welded, built-up "I" sections.
4.2.2. All endwall frames and columns shall be either cold-formed, mill rolled or built up "I" sections, depending on design requirements.
4.2.3. All main frame webs, baseplates, splice plates and flanges shall be shop fabricated to include holes for installation of bolts and slots for bracing.
4.3. SECONDARY FRAMING
![]() |
![]() |
4.4. BRACING
![]() |
![]() |
5.1. PANEL DESCRIPTION
![]() |
6.1. FASTENERS
![]() |
6.2. SEALANTS
![]() |
6.3. FLASHING, CLOSURE AND TRIM
![]() |
![]() |
7.1. PERSONNEL DOORS
7.1.1. Personnel doors shall be insulated standard 1- 3/4" full flush 20 gauge swing doors complete with a standard duty cylindrical lock. All doors shall also include flush hinges, door sweep, threshold and structural sub-jambs of Cee sections to insure rigid placement. (First girt usually acts as door header.) Flashing included to close off panel edges. Door sizes are standard 3070, 4070, 6070 (specify which).Other sizes available upon request. Panic, special hardware, and window frames cut into doors available upon request. Glazing not by WedgCor, Inc. Personnel doors are field located.
7.2. TRANSLUCENT PANELS
7.2.1. Translucent panels shall have the same configuration as the specified covering with an embossed finish exposed to the weather. Translucent panels shall be of translucent polyester resin reinforced glass fiber. The polyester used shall be specially formulated to produce a weather resistant, sun resistant, stabilized product.
7.3. OVERHEAD DOOR FRAMING
7.3.1. Overhead door framing shall be designed to resist applicable wind loads and shall consist of 8" or 9" Cee section jambs and header.
7.3.2. Galvanized flashing painted white (burnished slate is optional) shall be provided to conceal and close off panel edges around openings when steel siding is utilized. The flashing shall be of a type to completely conceal the red iron door framing. Partial flashing available at reduced cost.
7.3.3. Special flashing available to close off framed openings, if required, when other than steel siding is utilized. Details and shipping list must be supplied.
7.3.4. Overhead doors not by WedgCor, Inc.
7.4. WINDOW FRAMING
7.4.1. Window framing shall consist of Cee section for jambs, header and sill to insure rigidity. First girt usually acts as window header. Flashing included to close off panel edges and conceal the red iron window framing. Special flashing available, if required to seal off window framed opening when other than steel siding is utilized. Details and shipping list must be supplied.Glazing not by WedgCor, Inc.
7.5. VENTILATORS
7.5.1. Stationary roof ventilators are gravity type, manufactured from 24 gauge galvanized steel in which all welds, soldered seams, rivets and fasteners are clean, tight and secure. Ventilators feature seamless spun caps which are leak proof. Straight through drainage eliminates clogging by airborne debris. Mounting jack matches roof slope.
Vents utilize negative air pressure through a 14" throat as an operating principle. Overall width of vent is 22" and height 10 1/2", not including mounting jack dimension.
Power ventilation can be added before or after installation by adding fan section.
7.5.2. Spinning turbine vents use pre-lubricated ball bearing action for easy operation of rotor head. Suction is maintained through 12" throat even at low wind velocities. 360' operating surface assures access to wind currents regardless of direction.
The vents rotor shaft and bearing assembly are manufactured in galvanized steel and are encased in a corrosion resistant housing to assure long operational life.
Turbine, minus jack, is 15" high and 17 1/2" wide, with 22 rotor blades. Mounting jacks matches roof slope.
7.5.3. Ridge ventilators come in 10' sections with 9" or 12" throat (specify which), dampers and 15' chain loop, controlled by a worm gear operator to adjust damper. (Longer chain loop available as option).
7.6. LOUVERS
7.6.1. Wall louvers are standard 21" x 21" with 1-1/2" perimeter mounting flange making overall dimension 24" x 24" (other sizes available on special request). Pull chain against spring loading allows easy louver adjustment from convenient height.
Frame manufactured from 16 gauge galvanized roll formed channel with pre-slotted mounting holes with reinforced corners. Roll formed blades with three reinforcing ribs are pivoted off center and are linked together to operate in unison.
Cee section jambs, header and sill with trim, (similar to window framing detail) included for mounting louver unit to building and to insure rigidity.
8.1. ERECTION
8.1.1. The erection of the building and the installation of the accessories, shall be performed in a workmanlike manner with the proper tools and equipment, by a qualified erector, as set forth in the specifications and the manufacturer's erection drawings.
8.1.2. WedgCor, Inc. is not responsible for erection.
8.1.3. Upon request, the Manufacturer or its Marketing Service may supply the name(s) of potential contractors to install concrete and erect the building components or to perform other work pertaining to the installation and erection of the building components. Buyer acknowledges that neither the Manufacturer nor its Marketing Service have investigated such contractors, and that the provision of the name(s) does not constitute a recommendation of the skill or competence of any contractor. Buyer agrees to rely solely on his own investigation of such matters when selecting contractor. The Manufacturer and its Marketing Service are not involved in construction; any representation or agreement between Dealer or Contractor and Buyer concerning delivery, construction, modifications or other items are between the parties thereto, and do not bind the Manufacturer or its Marketing Service in any way.
8.2. FIELD MODIFICATION
8.2.1. Field design modifications will not be made to any structural member except as authorized and specified by the building manufacturer and approved and certified by the manufacturer's Engineer.
9.1. ANCHOR BOLTS
9.1.1. The building anchor bolts shall be designed to resist the column reaction. The sizes and design shall be as specified by the building manufacturer. (Anchor bolts and templates are not furnished by WedgCor, Inc.). The building manufacturer shall furnish anchor bolt setting plans.
9.2. FOUNDATIONS
![]() |
| Suggested specifications subject to change to equal or better without notice, due to our policy of continuous product improvements, fluctuations in material supply and market conditions. WedgCor, Inc. reserves the right to assign funds to others or to substitute manufacturing, engineering and raw materials, so long as the design, certified LL/WL and material specifications are equal to or exceed order requirements. |